在線咨詢

QQ咨詢

獲取報價

證書查詢

頂部

連接器UL1977認(rèn)證過載測試要求

文章來源 : 廣東優(yōu)科檢測 發(fā)表時間:2019-05-17 瀏覽數(shù)量:

廣東優(yōu)科檢測是UL授權(quán)第三方檢測機構(gòu),實驗室具備UL1977免目擊測試資質(zhì),可提供適用于UL1977標(biāo)準(zhǔn)的連接器UL認(rèn)證、檢測和技術(shù)咨詢服務(wù)。接下來為大家介紹連接器UL1977認(rèn)證過載測試要求。


連接器UL1977認(rèn)證


UL1977連接器產(chǎn)品分類

UL1977連接器產(chǎn)品分類


過載測試方法


測試對象:Female device,針對female連接器

測試條件:

Current ( A )150% rated current
Potential ( V )95~105% rated voltage
Power factor0.75 ~ 0.80, only for ac
Grounding Fuse ( A )15 Arating-current < 30 A
30 Arating-current > 30 A
Insert and withdraw with current
50 c, < 10 c/min


不需要做過載測試的情況
?
1. A Type 0 device
Type 0類型的連接器


2. A device is marked in accordance with “Not for  current interrupting “ or “For disconnecting use only  “ or with an equivalent statement.
設(shè)備按照“不用于當(dāng)前中斷”或“僅用于斷開連接”或使用等效聲明進(jìn)行標(biāo)記。


3. A female contact device interlocked with an integral  switch or other means such that the circuit is opened  before a mating male contact device can be inserted  or withdrawn.
一個母連接頭裝置與一體式開關(guān)或其他裝置互鎖,使得電路在插入或拔出配合的公連接頭裝置之前打開。


結(jié)果判定


1. No any electrical or mechanical failure of  the device nor pitting or burning of the  contacts that would affect the intended  function.
連接器電氣或機械結(jié)構(gòu)不失敗,接觸件的蝕損  或灼燒不影響使用功能。


2.The grounding fuse not open during the  test.

測試過程中接地保險絲不能斷開。


以上就是關(guān)于連接器UL1977認(rèn)證過載測試要求的介紹,如果您有連接器產(chǎn)品需要辦理UL認(rèn)證,歡迎聯(lián)系廣東優(yōu)科檢測工程師!